Type Of Breast Pump And The Affect To Pain Scale, Milk Production, And Pumping Time In Breastfeeding Mothers
Main Article Content
Abstract
Background: As we know that breastfeeding saves children under five lives every year, especially during the Covid-19 pandemic. The facts show that only 43% of infants 0-6 months are exclusively breastfed. The limited time for breast milk expression in between the mother's work routine needs to be supported by an efficient and effective pump. This study aimed to assess the type of breast pump not affect to pain scale, milk production, and pumping time in breastfeeding mothers.
Methods: This research is a cross-sectional study with a sample of 36 breastfeeding mothers in Banyumas Regency. They were chosen by distributing survey invitations through the WhatsApp group with a background breastfeeding mothers. Data was collected using the Google form, and analyzed using the Chi Square statistical test with a significance level of 95% (Alpha 0.05).
Results: Chi-Square analysis test shows the Asymp value. Sig. (2-sided) for the relationship between the type of Breast Pump and the Pain Scale, the volume of breast milk expressed, and the duration of pumping are 0.001; 0.905; 0.620, so only pain scale which less than α >0,05, the others are more than α >0,05. This result means any correlation between the type of breast pump with pain scale but no correlation with the amount of milk expressed, and the time spent pumping.
Conclusion: There is no relationship between the type of breast pump, the amount of milk expressed, and the time spent pumping, but any correlation between pain scale. So breastfeeding mothers can choose any breast pump that fits their needs and consider other factors influencing breastfeeding success.
Article Details
References
Ambarwati, E. R., Susanti, S. and Risdayanti, R. (2021) ‘PARTICIPATORY APPRAISAL RURAL: ASUHAN KEBIDANAN BERKELANJUTAN SEBAGAI MODEL PENDAMPINGAN KELUARGA DALAM PELAYANAN KEBIDANAN’, JMM (Jurnal Masyarakat Mandiri), 5(1), pp. 196–205. doi: 10.31764/jmm.v5i1.3748.
Amir, L. H., Baeza, C., Charlamb, J. R., & Jones, W. (2021). Identifying the cause of breast and nipple pain during lactation. bmj, 374.
Anggreni, S. et al. (2018) ‘PENGARUH PENGGUNAAN METODE POMPA ASI (MPA) TERHADAP PEMBERIAN ASI EKSLUSIF PADA IBU PEKERJA DI WILAYAH TOLOGOMAS KOTA MALANG’, Nursing News : Jurnal Ilmiah Keperawatan, 3(1). doi: 10.33366/NN.V3I1.747.
Becker, G. E., Smith, H. A. and Cooney, F. (2016) ‘Methods of milk expression for lactating women’, Cochrane Database of Systematic Reviews. John Wiley and Sons Ltd, 2016(9). doi: 10.1002/14651858.CD006170.PUB5/EPDF/ABSTRACT.
Crossland, N. et al. (2016) ‘Breast pumps as an incentive for breastfeeding: a mixed methods study of acceptability’, Maternal & Child Nutrition. Wiley-Blackwell, 12(4), p. 726. doi: 10.1111/MCN.12346.
Dewi, U. M. and Windarti, Y. (no date) ‘Efektivitas Pompa Air Susu Ibu: Studi Kasus pada Ibu Bekerja (Effectiveness of Breastfeed Pumps: Case Study on Working Mothers)’.
Gardner, H. et al. (2019) ‘Comparison of maternal milk ejection characteristics during pumping using infant-derived and 2-phase vacuum patterns’, International Breastfeeding Journal. BioMed Central Ltd., 14(1), pp. 1–8. doi: 10.1186/S13006-019-0237-6/FIGURES/4.
Gumasing, M. J. J., Villapando, A. C. and Siggaoat, C. D. (2019) ‘An ergonomic design of breastfeeding chair for Filipino mothers’, PervasiveHealth: Pervasive Computing Technologies for Healthcare. ICST, pp. 280–284. doi: 10.1145/3335550.3339901.
Kemenkes RI (2018) ‘Hasil Riset Kesehatan Dasar Tahun 2018’, Kementrian Kesehatan RI, 53(9), pp. 1689–1699.
Kumala, H. R. and Purnomo, W. (2019) ‘Hubungan ASI Eksklusif dengan Perkembangan Balita yang Memiliki Riwayat Berat Badan Lahir Rendah (BBLR) di Puskesmas Tanah Kali Kedinding Surabaya’, Media Gizi Kesmas. Universitas Airlangga, 8(2), pp. 33–39. doi: 10.20473/MGK.V8I2.2019.33-39.
Khayati, F. N., & Sulistiyowati, D. (2019). Penggunaan Pompa Air Susu Ibu (ASI) Elektrik Oleh Ibu Bekerja. Jurnal SMART Kebidanan, 6(2), 87-92.
Maula, S. N. and Widyawati, M. N. (2017) ‘THE EFFECT OF ELECTRIC BREAST PUMP IN INCREASING BREASTMILK PRODUCTION’, Proceedings of the International Conference on Applied Science and Health, (2), pp. 129–134. Available at: https://publications.inschool.id/index.php/icash/article/view/136 (Accessed: 23 November 2021).
McInnes, R. J., Gillespie, N., Crossland, N., Hall Moran, V., & Hoddinott, P. (2019). Women's views about a free breast pump service: Online survey informing intervention development. Maternal & child nutrition, 15(2), e12745. https://doi.org/10.1111/mcn.12745
Rini, S., & Kumala, F. (2017). Panduan Asuhan Nifas dan Evidence Based Practice. Deepublish.
Slusher, T. et al. (2007) ‘Electric breast pump use increases maternal milk volume in African nurseries’, Journal of tropical pediatrics. J Trop Pediatr, 53(2), pp. 125–130. doi: 10.1093/TROPEJ/FML066.
Vony Nurul Khasanah, 131411131061 (2019) ‘ANALISIS FAKTOR YANG BERHUBUNGAN DENGAN PEMBERIAN ASI EKSKLUSIF OLEH IBU PEKERJA PABRIK DI WILAYAH PUSKESMAS KALIRUNGKUT SURABAYA’. Available at: http:///lib.unair.ac.id (Accessed: 23 November 2021).